The IOLB-7014 provides four configurable differential analog inputs. The IOLB-7014 is intended to be connected directly to an IO-Link Master without an additional coupler box.
The small IOLB-7014 form factor of only 126 x 30 x 26.5 mm (h x w x d), which means that they are suitable for use where space is at a premium. The small mass of the IOLB-7014 module facilitates applications with mobile I/O interface (for example, a robot arm).
The robust design of the IOLB-7014 module enables them to be used directly at the machine. Control cabinets and terminal boxes are now no longer required. The module is fully sealed and therefore ideally prepared for wet, dirty or dusty conditions (IP67).
Pre-assembled cables significantly simplify IO-Link and signal wiring. Very few wiring errors are made, so that commissioning is optimized. In addition to pre-assembled IO-Link, power and sensor cables, field- configurable connectors and cables are available for maximum flexibility. Sensors and actuators are connected through M12 connectors.
Includes:
- IOLB-7014
- X1 protective cap
- Channel labeling tabs
Hardware
- Communication InterfaceIO-Link
- EnclosureIndustrial housing PA6 (polyamide)
- Ingress Protection RatingIP65, IP66, IP67 (conforms to EN 60529)
- Ports1 – IO-Link
4 – Analog Inputs
- Connector type (IO-Link)M12, 5-poles, A-coded (male)
- Connector type (Analog inputs)M12, 4-poles, A-coded (female)
- Connector ContactsPlated CuZn
- Mounting methodMachine or panel mount
- Mounting mechanismTwo mounting holes on the product for M3 screws
- LED IndicatorsIO-Link Communication status, Power Input L+, Power Input 2L+, Analog Input status
- Dimensions (L x W x H)126 x 30 x 26.5 mm
5“ x 1.2“ x 1“
- Weight125g
4.4 oz
Electrical Specifications
- Operating voltage18 – 30 VDC
- Nominal Voltage24 VDC
- Electronic module supplyL+ (Pin 1, 3 on IO-Link Connector X1)
- Supply of sensors2L+ (Pin 2, 5 on IO-Link Connector X1)
- Electrical isolationYes (between L+ and 2L+)
- Current consumption (module electronics)100 mA from L+
IO-Link Communication Specifications
- CommunicationIO-Link
- Operating modeCOM3 (230.4 kbps)
- StandardIEC61131-9
- IO-Link Device ID7014 (decimal)
00 1B 66 (hex)
- IO-Link Connector1 x M12, 5-poles, A-coded
- Specification VersionIO-Link V1.1
- IODD FilesYes
- FeaturesData storage
- Process Data Input (PDI)16 Bytes
- Process Data Output (PDO)0 Bytes
- Process imageInputs: 4 x 16 bit
Status: 4 x 16 bit
Analog Input Specifications
- Number of Analog Inputs4
- Input Connectors4 x M12, 5-pole, A-coded socket
- Input TypesConfigurable:
• 0 V ... + 10 V
• -10 V ... + 10V
• 0 mA ... 20 mA
• 4 mA ... 20 mA
- Internal Resistance> 200K ohms (typ. 85 Ω + diode voltage)
- Resolution16 bits (incl. Sign)
- Input FilterConfigurable
- Input filter cut-off frequency5 kHz
- Conversion time~ 100 microseconds
- Measurement Error<± 0.3% (relative to the full-scale value)
-
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
- 4 channel analog input IO-Link Block (Class B)
- M12 connectors
- Provides user scale and filters
- Input either voltage or current
- IP65/66/67
- Parameterization using IO-Link for easy installation and configuration
- Data Storage capable for easy device replacement
- IODD files
|
|
|
|
|
|
|